HM100 Integrated Temperature Transmitter

Factory-calibrated 4-20mA temperature transmitter with universal thermocouple and RTD input. True 2-wire operation with ±0.1% accuracy and optional explosion-proof certification.

±0.1% Accuracy 4-20mA Output 2-Wire Operation Ex-Proof Options Universal Input IP65 Rated

HM100 Integrated Temperature Transmitter

Why Choose HM100 Integrated Temperature Transmitter?

Need help choosing the right configuration? Before specifying an HM100 head-mount transmitter, review our industrial temperature sensor selection guide for a two-stage decision framework that walks through sensing element class and assembly type.

Integrated Design

Sensor and transmitter pre-calibrated as a single unit—no extra setup required. Delivers consistent ±0.1% accuracy across the entire measurement range.

True 2-Wire

Standard 4-20mA operation requires only two wires for both power and signal. Reduces installation complexity and wiring costs in demanding field environments.

Explosion-Proof

Available with ATEX certification (dIIBT4, dIICT5, dIICT6, iaIICT6) for safe operation in hazardous gas, vapor, and dust environments.

Universal Input

Supports thermocouple types K, N, E, J, T, S, R, B and RTD Pt100. Single device handles multiple sensor types—simplifies inventory management.

Industrial Grade

316L stainless steel, IP65 protection, and certified performance in harsh chemical and corrosive environments. Built for decades of reliable service.

Smart Options

Optional HART protocol for two-way device communication and remote configuration. Available with LCD/LED display for local indication.

Technical Specifications

Parameter Specification
Temperature Range (Thermocouple) -200°C to +1300°C
Temperature Range (RTD Pt100) -200°C to +500°C
Output Signal 4-20mA (standard) | 0-10mA (optional)
Accuracy ±0.1% | ±0.2% | ±0.5% of calibrated span
Power Supply 24V DC ±10%
Load Resistance (4-20mA) ≤250Ω | (0-10mA) ≤500Ω
Transmission Distance Up to 1000m
Response Time (Φ16 Sheath) <24 seconds
Response Time (with Thermowell) <120 seconds
Sheath Materials 304 SS, 316L SS, Inconel 600, Hastelloy C276
Sheath Diameter Φ4, Φ6, Φ8, Φ10, Φ12, Φ16 mm
Insertion Length 250~2150 mm (customizable)
Process Connection Fixed screw thread | Fixed flange | Straight pipe joint
Protection Grade IP65
Explosion-Proof dIIBT4, dIICT5, dIICT6, iaIICT6 (optional)
Insulation Resistance ≥50MΩ at 100VDC
Operating Environment -25°C to +80°C, humidity 5~95% RH
HART Communication Optional (smart model)
Display LCD/LED (optional)
Standards IEC 584, IEC 60751, GB/T26786-2011, CE, Ex (ATEX optional)

Key Features

Factory-Calibrated Integration

Sensor and transmitter are calibrated as a single integrated unit, ensuring maximum accuracy and eliminating setup errors in the field.

True 2-Wire Operation

Standard 4-20mA output requires only two wires for both power supply and signal transmission—reduces wiring complexity in field installations.

Explosion-Proof Options

ATEX certified (dIIBT4, dIICT5, dIICT6, iaIICT6) for safe operation in hazardous areas with explosive gas, vapor, or dust atmospheres.

Universal Sensor Input

Accepts all thermocouple types (K, N, E, J, T, S, R, B) and RTD Pt100 sensors. One device replaces multiple single-purpose transmitters.

Rugged Industrial Design

316L stainless steel construction with IP65 protection rating. Designed to withstand harsh chemical, corrosive, and high-temperature environments.

HART Communication

Optional HART protocol for two-way communication and remote device configuration. Available on smart model variants.

Industry Applications

Oil & Gas

Wellhead temperature monitoring, refinery process control, pipeline integrity testing, and downhole thermal measurements in extreme pressure/temperature conditions.

Chemical/Petrochemical

Reactor temperature monitoring, distillation column control, heat exchanger performance tracking, and corrosive liquid process management.

Food & Beverage

Pasteurization and sterilization process control, fermentation tank monitoring, cold chain management, and steam system temperature tracking.

Metals & Glass Manufacturing

Furnace temperature control, annealing process monitoring, molten metal measurement, and kiln management in extreme thermal environments.

HVAC & Building Automation

Chiller/boiler monitoring, zone temperature control, supply/return temperature differential measurement, and demand-controlled ventilation systems.

Pharmaceutical

Cleanroom environment monitoring, pharmaceutical process validation, incubator/refrigerator temperature surveillance, and stability testing chambers.

Model Code & Ordering Guide

Example: HM100 – K – F – Φ8 – 300 – dIIBT4 – LCD

Position Parameter Options
1 Model HM100 (standard)
2 Sensor Type K, N, E, J, T, S, R, B (Thermocouple) | Pt (RTD)
3 Output F (4-20mA) | O (0-10mA)
4 Sheath Diameter Φ4, Φ6, Φ8, Φ10, Φ12, Φ16 mm
5 Insertion Length 250–2150 mm (customizable, e.g., 300, 500, 1000)
6 Protection – (none) | dIIBT4 | dIICT5 | dIICT6 | iaIICT6
7 Display – (none) | LCD | LED

Frequently Asked Questions

The HM100 is an integrated transmitter—sensor and signal conditioning are factory-calibrated as a single unit with a standard head mount. The SBW is a head-mounted transmitter that mounts directly on the sensor’s connection head (on process equipment). Choose HM100 for standalone transmitters with separate sensor connections; choose SBW when you want to mount the transmitter directly on existing sensors.

Yes, the HM100 is available with ATEX explosion-proof certification (dIIBT4, dIICT5, dIICT6, iaIICT6). These variants are designed for safe operation in hazardous areas with explosive gas, vapor, or dust. Specify your hazard group and category when ordering. Standard HM100 units are not rated for explosive atmospheres.

Type K: Most common (-200°C to +1300°C), general-purpose • Type J: Iron-constantan, narrower range (-40°C to +750°C), ferrous applications • Type N: Nicrosil-Nisil, high-temperature stable, low drift • Type T: Copper-constantan, low temperatures (-200°C to +400°C) • Type E: High sensitivity, cryogenic to +1000°C • RTD Pt100: For precision measurements, -200°C to +500°C. Contact our engineers for application-specific recommendations.

“2-wire” means the HM100 requires only two wires to operate: one wire carries the 24V DC power supply, and the same two wires carry the 4-20mA output signal (the transmitter draws current from the power line proportional to temperature). This is vastly simpler than 3-wire or 4-wire configurations and reduces installation costs, wiring errors, and cable clutter in the field.

Yes, absolutely. The HM100 insertion length ranges from 250 mm to 2150 mm (fully customizable). Specify your exact length in the model code (e.g., HM100-K-F-Φ8-500 for 500mm). Custom lengths beyond this range may be available—contact our team for special requests.

Standard configurations typically ship within 2–4 weeks. Custom sheath materials (Inconel, Hastelloy), explosion-proof variants, or HART codels may require 4–8 weeks. Expedited options available upon request. Contact our engineers with your specifications for an exact delivery estimate.

Ready to Upgrade Your Temperature Measurement?

Our engineering team will help you select the ideal HM100 configuration for your application—whether you need explosion-proof ratings, custom sheath materials, or HART communication.

We’ll respond with detailed technical specifications, pricing, and delivery estimates within 12 business hours.

Cross-check HM100 Readings with Our Free TC Calculator

When commissioning an HM100, it is useful to compare the smart-transmitter output against the raw IEC 60584 EMF tables. Our free calculator converts mV ↔ °C for all 8 thermocouple types with selectable CJC modes — same math the HM100 runs internally, exposed for your bench-test workflow.

Open Thermocouple Calculator →