HE Series — Miniature Pressure Sensors

HE91 Miniature Pressure Transmitter

Ultra-compact pressure transmitter weighing under 20 g, designed for space-constrained installations. Piezoresistive silicon strain gauge technology delivers ±0.5% FS accuracy across 100 kPa to 70 MPa, with optional flush diaphragm achieving 3 kHz dynamic response for demanding test and OEM applications.

Range: 100 kPa–70 MPa

Weight: <20 g

Accuracy: ±0.5% FS

CE Certified

HE91 Miniature Pressure Transmitter

Product Overview

The HE91 Miniature Pressure Transmitter is an ultra-compact, integrated pressure sensor designed for applications where installation space is severely limited or sensor weight must be minimized. Weighing less than 20 grams (without cable), it delivers full transmitter-grade performance in a package small enough for embedded OEM systems, robotic end-effectors, and portable test equipment.

The sensing element uses a temperature-compensated Wheatstone bridge diffused onto a high-stability micro-machined silicon strain gauge substrate, ensuring excellent accuracy and repeatability. The compact body can be optionally constructed entirely from titanium alloy for corrosion resistance in harsh environments while maintaining minimal weight.

Available with an optional G3/8 flush diaphragm design, the HE91 achieves up to 3 kHz dynamic frequency response — making it suitable for both static process monitoring and dynamic pressure testing. Standard threaded configurations (M5×0.8, M6×1, M8×1) deliver 1 kHz response bandwidth. With pressure ranges from 100 kPa to 70 MPa in both gauge and absolute reference types, the HE91 serves as a versatile platform for demanding miniature pressure measurement across aerospace, automotive, biomedical, and defense applications.

Technical Specifications

ParameterSpecification
Pressure Range100 kPa – 70 MPa (1 bar – 700 bar)
Reference TypeGauge / Absolute
Sensing TechnologyPiezoresistive silicon strain gauge (micro-machined)
Accuracy (Combined)±0.5% FS (default), ±0.25% FS (option T1), ±0.1% FS (option T2)
Long-Term StabilityTypical ±0.1% FS/year, Max ±0.2% FS/year
Resolution0.01% FS
Natural Frequency500 kHz
Response Frequency0–1 kHz (threaded), 0–3 kHz (flush diaphragm G3/8)
Overload Capacity1.5–2× rated pressure
Burst Pressure4× FS (≤100 MPa)
Cycle Durability>10⁷ cycles
Output Signals4-20 mA, 1-5 V, 0-5 V, 0.5-4.5 V
Supply Voltage9–30 VDC (current) / 12–36 VDC (voltage)
Media Temperature-40°C to +100°C (special: -55°C to +150°C)
Ambient Temperature-40°C to +85°C
Compensation Range-20°C to +70°C (special: -40°C to +120°C)
Zero Temp DriftTypical ±0.01% FS/°C, Max ±0.02% FS/°C
Sensitivity Temp DriftTypical ±0.01% FS/°C, Max ±0.02% FS/°C
Vibration Resistance20 g (IEC 60068-2-6)
Shock Resistance500 g / 1 ms (IEC 60068-2-27)
Weight<20 g (without cable)
Housing MaterialStainless steel 316L (standard) / Titanium alloy (option T3)
Process ConnectionM5×0.8, M6×1, M8×1, G3/8 flush diaphragm, custom
Electrical ConnectionDirect cable (1 m), M8 right-angle (1 m), XS9 aviation connector (1 m)
Protection RatingIP65 (connector) / IP67 (cable/integrated)
EMCEN 61000-6-3 (emission), EN 61000-6-2 (immunity)
CertificationsCE

Key Features

Applications

Ordering Guide

Use the model code structure below to specify your HE91 configuration. For custom requirements or assistance, contact our engineering team.

Model Code: HE91 – [Reference] – [Range] – [Output] – [Thread] – [Electrical] – [Options]

PositionCodeDescription
Reference TypeGGauge pressure
AAbsolute pressure
Pressure Range001B…700B1 bar to 700 bar (specify full-scale, e.g., 016B = 16 bar)
Output SignalA14-20 mA (2-wire)
V11-5 V (3-wire)
V20-5 V (3-wire)
V30.5-4.5 V (3-wire)
V40.5-4.5 V / 5 V ratiometric
Process ConnectionF1M6×1 external thread
F2M8×1 external thread
F3M5×0.8 external thread
F4G3/8 flush diaphragm
F0Custom (specify)
Electrical ConnectionW1Direct cable outlet (1 m)
W3M8 right-angle connector (1 m)
W4XS9 aviation connector (1 m)
OptionsT1Enhanced accuracy ±0.25% FS
T2High accuracy ±0.1% FS
T3All-titanium housing
TSpecial requirements (specify)

Example: HE91-G-016B-A1-F1-W4-T1 = Gauge type, 16 bar range, 4-20 mA output, M6×1 thread, XS9 aviation connector, ±0.25% FS accuracy

Frequently Asked Questions

The HE91 weighs less than 20 grams without cable — roughly 5 to 10 times lighter than a standard industrial pressure transmitter, which typically weighs 100–200 grams. Its smallest thread option (M5×0.8) makes it one of the most compact integrated pressure transmitters available, suitable for applications where standard sensors simply cannot fit.

The G3/8 flush diaphragm eliminates the dead volume (cavity) found in standard threaded pressure ports. This provides two key benefits: first, it triples the dynamic frequency response from 1 kHz to 3 kHz, enabling faster pressure transient capture; second, it prevents media from becoming trapped in a cavity, which is important for hygienic applications and viscous fluids that could clog a traditional pressure port.

Yes. Despite its miniature size, the HE91 is built to military-grade shock and vibration standards. It withstands 500 g mechanical shock (1 ms pulse, per IEC 60068-2-27) and 20 g continuous vibration (per IEC 60068-2-6). These ratings make it suitable for automotive crash testing, aerospace flight systems, and defense applications where extreme mechanical stress is expected.

The T3 all-titanium housing option replaces the standard stainless steel body with titanium alloy, which offers superior corrosion resistance (especially in saltwater, acidic, and chloride environments) while being approximately 40% lighter than steel. This makes it ideal for marine, aerospace, and chemical processing applications where both weight reduction and corrosion resistance are priorities.

The HE91 offers three accuracy tiers: standard ±0.5% FS (included), enhanced ±0.25% FS (option T1), and high-precision ±0.1% FS (option T2). All accuracy specifications include combined linearity, hysteresis, and repeatability errors. The temperature compensation range is -20°C to +70°C standard, expandable to -40°C to +120°C for extreme environments.

Need a Miniature Pressure Sensor for Your Application?

Our engineering team can help you select the optimal HE91 configuration for your space-constrained application — including thread size, accuracy grade, housing material, and output signal. Whether you need a single prototype or volume OEM quantities, we provide full technical support.

Our engineers typically respond within 12 business hours with detailed technical specifications and pricing.