HPTM SERIES · DUAL OUTPUT

HPTM189 Integrated Temperature & Pressure Transmitter

Independent measurement of process pressure and temperature in a single transmitter. Pressure accuracy ±0.5% FS (±0.2% FS option), temperature accuracy ±0.5°C from -40 to 200°C. Pressure ranges to 40 MPa gauge or 10 MPa absolute. Front-mounted PT100/PT1000 element gives smaller ΔT vs. traditional pocket-mounted thermometers.

±0.5% FS Pressure ±0.5°C Temperature 0–50 kPa to 40 MPa -40 to 350°C Modbus · 4-20 mA · 0-10 V IP65 / IP66 / IP67 304 / 316L Wetted
HPTM189 Integrated Temperature & Pressure Transmitter

Product Overview

The HPTM189 combines a high-stability piezoresistive silicon pressure sensor with a precision PT100 or PT1000 RTD element in a single compact transmitter housing. Both signals are conditioned independently and output through standard industrial protocols, so a single instrument and one cable run can deliver pressure and temperature data to the same DCS or PLC channel.

The temperature element sits at the front of the housing, in direct proximity to the process media. Compared with traditional pocket-mounted thermometers, the front-mount geometry shortens the heat path, reduces the introduced ΔT, and gives faster step response on changing media. A breathable design on the small-pressure-range models keeps the reference port dry while letting ambient pressure equalise — the result is more stable low-range readings without separate venting.

The HPTM189 is suited to industrial process control applications where one measurement point must report both pressure and temperature accurately — refrigeration loops, hydraulic and pneumatic systems, lab and pilot rigs, and chemical process skids where panel space or cable counts are constrained.

Technical Specifications

ParameterSpecification
Pressure range (gauge)0–50 kPa to 0–40 MPa, intermediate ranges customizable; negative pressure supported
Pressure range (absolute)0–50 kPa to 0–10 MPa, intermediate ranges customizable
Pressure overload2× rated, e.g., 2 MPa range → 4 MPa overload
Temperature range-40 to 200°C standard; -40 to 350°C custom (9-fin, micro-pore housing)
Pressure accuracy±0.5% FS (standard), ±0.2% FS (improved class)
Temperature accuracy±0.5°C (-40°C ≤ media ≤ 200°C); ±1.0°C (200°C < media ≤ 350°C)
Long-term stability±0.25% FS / year
Pressure response time≈ 20–100 ms; warm-up ≤ 5 s
Temperature drift (pressure channel)Zero ±1.5% FS / Span ±1.5% FS over -10 to 70°C compensated band
Output optionsDual 4-20 mA · Dual 0-5 V · Dual 0-10 V · Pressure 4-20 mA + Temperature PT100/PT1000 (3-wire) · 4-wire Modbus-RTU / RS485
Supply voltage10–30 VDC standard; 8.5–30 VDC for 0-5 V; 12–30 VDC for 0-10 V; 3.1–8 VDC battery low-power Modbus mode
Ambient operating-40 to 85°C; storage -40 to 85°C
Media temperature housing5-fin: -40 to 140°C · 9-fin: -40 to 200°C · 9-fin micro-pore: -40 to 350°C
ProtectionIP65 (Hirschmann DIN43650) · IP66 (M12×1) · IP67 (direct cable)
Vibration / Shock20 g (20–5000 Hz) / 50 g (11 ms)
Insulation>20 MΩ @ 500 VDC; dielectric < 2 mA @ 500 VAC for 1 min
Wetted materialsPressure port 304 (S4) or 316L (S6); sensor 316L (M1); O-ring FKM (F1)
Electrical interfaceHirschmann DIN43650, M12×1 (4P / 5P), M12×1 with cable, direct cable
Reverse polarityNo damage; circuit non-functional under reversed wiring
Short-circuit protectionSupported on output

Key Features

Applications

Wiring & Electrical Interface

The HPTM189 supports four electrical interface families, each with a published pinout. Match the connector to the existing panel hardware first; signal-output choice (4-20 mA, 0-5 V, 0-10 V, or Modbus) is independent.

Output typeHirschmannDirect cableM12×1-5P
Pressure 4-20 mA + Temperature PT100/PT1000 (3-wire)+V=1, 0V/+OUT=2, A=3 (B routed via cable for RTD)Red=+V, Black=0V, Blue=A, Yellow=B, Green=B1=+V, 3=0V, 2=A, 4=B, 5=B
Dual 4-20 mA (Pressure 2-wire + Temperature 2-wire)+V=1, 0V/+OUT=2, +V_T=3Red=+V_P, Black=0V_P, Yellow=+V_T, Green=0V_T1=+V_P, 3=0V_P, 2=+V_T, 4=0V_T
Dual 0-5 V or 0-10 V (3-wire)+V=1, GND=2, +OUT_P=3 (T routed separately)Red=+V, Black=GND, Yellow=+OUT_P, Green=+OUT_T1=+V, 3=GND, 2=+OUT_P, 4=+OUT_T
4-wire Modbus-RTU / RS485+V=1, -V=2, A=3, B (cable)Red=+V, Black=-V, Yellow=A, Green=B1=+V, 3=-V, 2=A, 4=B

RS485 with 24 V supply adds approximately 25 mm to the housing height. M12×1 wiring shifts to brown / blue / white / black / grey when supplied with pre-attached cable.

Ordering Guide

Model code: HPTM189 – (Range) – [Accuracy] – [Output] – [Connection] – [Electrical] – [Housing] – [Material]

PositionCodeDescription
Pressure rangee.g. 0~10MPaSpecify FS range; gauge or absolute on order
AccuracyA1 / A2A1 = ±0.5% FS standard; A2 = ±0.2% FS improved
Output signalO1 / O2 / O3 / O4 / O5O1 = pressure 4-20 mA + PT100 3-wire; O2 = dual 4-20 mA; O3 = dual 0-5 V; O4 = dual 0-10 V; O5 = Modbus-RTU RS485
ConnectionF0 / F-customStandard tap (M20×1.5, G1/4 or similar). Specify NPT or other custom thread on F0
Electrical interfaceC1 / C1.1 / C2 / C5 / C6C1 = standard Hirschmann; C1.1 = compact Hirschmann; C2 = direct cable IP67; C5 / C6 = M12×1 (5P / 4P)
Housing finsT5 / T9 / T9MT5 = 5-fin (media -40 to 140°C); T9 = 9-fin (-40 to 200°C); T9M = 9-fin micro-pore (-40 to 350°C)
Wetted materialS4 / S6S4 = pressure port 304; S6 = pressure port 316L (sensor 316L; FKM O-ring on both)
Probe extensionoptionalCustom RTD probe extension available for inserting the temperature element into pipe centerline

Example order: HPTM189-(0~10MPa)-A2-O1-F0(G1/4)-C1-T9-S6 (10 MPa range, ±0.2% FS pressure, 4-20 mA + PT100, G 1/4 process port, standard Hirschmann, 9-fin housing, 316L wetted).

FAQ

Both are dual-channel pressure + temperature transmitters. HPTM189 is wired (4-20 mA, 0-5/0-10 V, or Modbus over RS485) and powered from a regulated DC supply. HM200H is wireless via LoRa with internal battery, suitable for remote monitoring without cabling. Choose HPTM189 when the cable run already exists and the host is a DCS or PLC; choose HM200H when the measurement point is far from infrastructure.

Yes. The HPTM189 supports a custom probe-extension structure that places the PT100 / PT1000 element farther into the process media. Specify the desired insertion length when ordering. For pipes above DN50 the extended probe gives a more representative media-temperature reading than the housing-flush configuration.

Modbus-RTU on RS485 with the low-power supply mode (3.1 to 8 VDC). The transmitter can sleep between polls and only wakes when the master requests data, extending battery life by an order of magnitude versus continuous 4-20 mA operation. 4-20 mA loop current alone draws 4 to 20 mA continuously, which is unsuitable for solar-charged or primary-battery stations.

The integrated front element sits in the pressure-measurement port itself, so it reads the same media that the diaphragm sees. ΔT to the actual process is small and the response is fast. A separate thermowell with an RTD inside still works for many applications but adds installation labour, a second tap, and an additional thermal time constant. The HPTM189 is the better choice when one tap is enough and the installation cost matters.

IP65 (Hirschmann DIN43650) suits indoor and sheltered outdoor service; IP66 (M12×1) handles brief direct hose-down; IP67 (direct cable) is needed when the device sees occasional immersion or aggressive washdown. Note that the IP66 and IP67 housings disable the breathable design, so they are not the best choice for very low-range gauge pressure measurements (below 0~50 kPa). Match the protection class to the field environment first, then check the pressure range constraint.

Yes. Standard process taps are M20×1.5 and G 1/4. NPT and other thread families are available as a custom F0 option — specify the desired thread (for example, 1/4 NPT or 1/2 NPT) when placing the order. See our NPT vs BSP/G thread guide if you need to choose a thread family for a multi-region project.

Need a Combined Pressure & Temperature Solution?

Send your application details — range, media, ambient, output type, connector preference — and our pressure team will configure an HPTM189 model code with the correct accuracy class, housing, and wetted material. Custom probe extensions and intermediate ranges are available.

Our engineers typically respond within 12 business hours with detailed technical specifications and pricing.